Back to Search Start Over

Efficacy of 3D‐multidetector computed tomography and fluoroscopy fusion for percutaneous left atrial appendage occlusion procedures.

Authors :
Carneiro, Herman A.
Dallan, Luis A. P.
Yoon, Sung‐Han
Arora, Shilpkumar
Knezevich, Juliana
Wass, Sojin
Lobo, Tabitha
Arruda, Mauricio
Rashid, Imran
Filby, Steven J.
Source :
Journal of Cardiovascular Electrophysiology; Oct2023, Vol. 34 Issue 10, p2076-2083, 8p, 3 Color Photographs, 1 Black and White Photograph, 2 Graphs
Publication Year :
2023

Abstract

Introduction: We studied the impact of the use of three‐dimensional multidetector computed tomography (3D‐MDCT) and fluoroscopy fusion on percutaneous left atrial appendage occlusion (LAAO) procedures in relation to procedure time, contrast volume, fluoroscopy time, and total radiation. Methods: This was a single‐center, prospective, single‐blinded, randomized control trial. Patients meeting criteria for LAAO were randomized to undergo LAAO with the WATCHMAN FLXTM device with and without 3D‐MDCT‐fluoroscopy fusion guidance using a prespecified protocol using computed tomography angiography for WATCHMAN FLXTM sizing, moderate sedation, and intracardiac echocardiography for procedural guidance. Results: Overall, 59 participants were randomly assigned to the fusion (n = 33) or no fusion (n = 26) groups. The median (interquartile range) age was 79 (75–83) years, 24 (41%) were female, and 55 (93%) were Caucasian. The median CHA2DS2 VASc and HASBLED scores were 5 (4–6) and 3 (3–4), respectively. At the time of the study, 51 (53%) patients were on a direct acting oral anticoagulant. There were no significant differences between the fusion and no fusion groups in procedure time (52.4 ± 15.4 vs. 56.8 ± 19.5 min, p =.36), mean contrast volume used (33.8 ± 12.0 vs. 29.6 ± 11.5 mls, p =.19), mean fluoroscopy time (31.3 ± 9.9 vs. 28.9 ± 8.7 min, p =.32), mean radiation dose (1177 ± 969 vs. 1091 ± 692 mGy, p =.70), and radiation dose product curve (23.9 ± 20.5 vs. 35.0 ± 49.1 Gy cm2, p =.29). There was no periprosthetic leak in the two groups in the immediate 1‐month postprocedure follow‐up periods. Conclusions: There was no significant difference with and without 3D‐MDCT‐fluoroscopy fusion in procedure time, contrast volume use, radiation dose, and radiation dose product. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10453873
Volume :
34
Issue :
10
Database :
Complementary Index
Journal :
Journal of Cardiovascular Electrophysiology
Publication Type :
Academic Journal
Accession number :
172894349
Full Text :
https://doi.org/10.1111/jce.16035