Back to Search Start Over

Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography.

Authors :
Uetani, Hiroyuki
Kitajima, Mika
Ohmori, Yuki
Morita, Kosuke
Yamashita, Yuichi
Kaku, Yasuyuki
Nakaura, Takeshi
Sasao, Akira
Sasaki, Goh
Ishiuchi, Soichiro
Mukasa, Akitake
Hirai, Toshinori
Source :
European Radiology; Nov2023, Vol. 33 Issue 11, p7923-7933, 11p
Publication Year :
2023

Abstract

Objectives: As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. Methods: This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm<superscript>3</superscript> were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. Results: On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p <.001) and for open-cell type stents than closed-cell type (p <.01). Conclusions: 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. Key Points: • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09387994
Volume :
33
Issue :
11
Database :
Complementary Index
Journal :
European Radiology
Publication Type :
Academic Journal
Accession number :
173151737
Full Text :
https://doi.org/10.1007/s00330-023-09755-1