Back to Search
Start Over
Development of a CFD model indicating the quantitative relationship among reactor dimension, bed flow unevenness, and performance for VOCs biofilters.
- Source :
- Journal of the Air & Waste Management Association (Taylor & Francis Ltd); Nov2023, Vol. 73 Issue 11, p865-876, 12p
- Publication Year :
- 2023
-
Abstract
- This study presents a Computational Fluid Dynamics (CFD) based biofiltration model to investigate the airflow distribution and the impact of bed flow unevenness (BFU) on the removal of Volatile Organic Compounds (VOCs) in biofilters. The biofiltration model consists of a gas flow sub-model and a VOCs removal sub-model, which were validated by pilot-scale experiments. The model was used to examine the quantitative relationship among reactor dimensions, including the width to height ratio of the filter bed and empty bed residence time (EBRT), BFU, and performance for VOCs biofilters. Simulation results demonstrate that the flow unevenness index (FUI) of the packing layer changes from 0.06 to 0.48 m<superscript>2</superscript>‧s<superscript>−1</superscript> with reactor dimension changes. With an increase in the width to height ratio at a constant EBRT, FUI increases, BFU changes, and flow velocity fluctuation on the cross-section becomes larger, leading to a reduction of about 10% in VOCs removal efficiency. Concentration distribution of VOCs becomes uneven in the horizontal direction. At a constant width to height ratio of the filter bed, an increase in EBRT causes an increase in FUI, leading to a decrease in VOCs removal efficiency. When the width to height ratio is 0.5, velocity fluctuation of filter bed cross-section is small, the concentration of VOCs decreases evenly across the filter bed layer, and FUI is at a low level (0.06–0.11 m<superscript>2</superscript>‧s<superscript>−1</superscript>). Implication: In this manuscript, a biofiltration model of VOCs biofilter based on CFD has constructed and validated. And the manuscript gave the quantitative relationship among reactor dimension, bed flow unevenness and performance for VOCs biofilters for the first time. This study can lead to enhanced VOCs removal efficiency and improved overall performance of biofilters in practical engineering applications. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10962247
- Volume :
- 73
- Issue :
- 11
- Database :
- Complementary Index
- Journal :
- Journal of the Air & Waste Management Association (Taylor & Francis Ltd)
- Publication Type :
- Academic Journal
- Accession number :
- 173436701
- Full Text :
- https://doi.org/10.1080/10962247.2023.2267010