Back to Search Start Over

A dynamic calculation model of the carbon footprint in the life cycle of hospital building: a case study in China.

Authors :
Yue, Jianjin
Li, Wenrui
Cheng, Jian
Xiong, Hongxing
Xue, Yu
Deng, Xiang
Zheng, Tinghui
Source :
Engineering Construction & Architectural Management (09699988); 2023, Vol. 30 Issue 10, p4735-4761, 27p
Publication Year :
2023

Abstract

Purpose: The calculation of buildings' carbon footprint (CFP) is an important basis for formulating energy-saving and emission-reduction plans for building. As an important building type, there is currently no model that considers the time factor to accurately calculate the CFP of hospital building throughout their life cycle. This paper aims to establish a CFP calculation model that covers the life cycle of hospital building and considers time factor. Design/methodology/approach: On the basis of field and literature research, the basic framework is built using dynamic life cycle assessment (DLCA), and the gray prediction model is used to predict the future value. Finally, a CFP model covering the whole life cycle has been constructed and applied to a hospital building in China. Findings: The results applied to the case show that the CO<subscript>2</subscript> emission in the operation stage of the hospital building is much higher than that in other stages, and the total CO<subscript>2</subscript> emission in the dynamic and static analysis operation stage accounts for 83.66% and 79.03%, respectively; the difference of annual average emission of CO<subscript>2</subscript> reached 28.33%. The research results show that DLCA is more accurate than traditional static life cycle assessment (LCA) when measuring long-term objects such as carbon emissions in the whole life cycle of hospital building. Originality/value: This research established a carbon emission calculation model that covers the life cycle of hospital building and considered time factor, which enriches the research on carbon emission of hospital building, a special and extensive public building, and dynamically quantifies the resource consumption of hospital building in the life cycle. This paper provided a certain reference for the green design, energy saving, emission reduction and efficient use of hospital building, obviously, the limitation is that this model is only applicable to hospital building. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09699988
Volume :
30
Issue :
10
Database :
Complementary Index
Journal :
Engineering Construction & Architectural Management (09699988)
Publication Type :
Academic Journal
Accession number :
173861763
Full Text :
https://doi.org/10.1108/ECAM-05-2022-0395