Back to Search Start Over

Seismic Evaluation Approaches for Spent Fuel Pool Structures in Nuclear Power Plants.

Authors :
Hsu, Wei-Hung
Chai, Juin-Fu
Lin, Fan-Ru
Source :
International Journal of Structural Stability & Dynamics; Dec2023, Vol. 23 Issue 19, p1-31, 31p
Publication Year :
2023

Abstract

The United States Nuclear Regulatory Commission issued requests for licensees to re-evaluate the seismic hazards at their sites after the accident at the Fukushima Daiichi Nuclear Power Plant in Japan on March 11 in 2011 and to identify and address any site-specific vulnerabilities associated with seismic hazards. The primary guidance for performing those evaluations is provided in the Electric Power Research Institute EPRI-1025287 report, which also provides guidance for evaluating spent fuel pool (SFP) integrity. In addition, the EPRI-3002009564 report also provides evaluation approaches regarding the effects of seismic ground motions on SFPs that supplement the guidance provided in EPRI-1025287. SFP integrity has become increasingly important for active and decommissioned nuclear power plants. According to EPRI-1025287, the SFP integrity evaluation emphasizes failure modes of the SFP that could result in "rapid drain-down." The definition of "rapid drain-down" is a failure that could lead to the uncovering of irradiated fuel stored in the SFP within 72 h of an earthquake. Possible failures can be classified into two categories: failures relevant to the SFP structure and failures relevant to non-structural elements. This paper aims to study the approaches of implementing seismic evaluation of an SFP structure. EPRI-3002009564 provides separate seismic evaluation approaches for plants with a ground motion response spectrum (GMRS) peak Sa ≤ 0. 8 g and for plants with a GMRS peak Sa > 0. 8 g. Structural dynamic analysis is also a common approach for implementing seismic evaluation if a detailed finite element model is available. In this paper, a sample SFP structure was evaluated using the two approaches, structural dynamic analysis and structural analysis criteria. The results indicate that shear failure controlled the failure mode of the SFP structure for both approaches. This shows that the two approaches drew the same conclusion regarding the failure mode. Furthermore, a smaller seismic margin was obtained using the structural analysis criteria, which means this evaluative approach is more conservative. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02194554
Volume :
23
Issue :
19
Database :
Complementary Index
Journal :
International Journal of Structural Stability & Dynamics
Publication Type :
Academic Journal
Accession number :
174179597
Full Text :
https://doi.org/10.1142/S0219455423501882