Back to Search Start Over

Thermal performance comparison of closed loop pulsating heat pipe with DI water and Al2O3/DI nanofluid.

Authors :
Parmar, Kamlesh
Nagme, Ibrahim
Thakur, Sachin
Singh, Abhishek
Parwani, Ajit Kumar
Tripathi, Sumit
Parmar, Nirmal
Source :
AIP Conference Proceedings; 2024, Vol. 2960 Issue 1, p1-8, 8p
Publication Year :
2024

Abstract

Pulsating heat pipe (PHP) has been a research interest in the areas of thermal management in various engineering applications such as electronics cooling. The present work focuses on thermal performance improvement of a PHP by experimentally studying the effects of thermal parameters such as type of working fluids (nanofluid and deionised water), temperature range, and filling ratios on thermal resistance of the PHP. Experimental studies are conducted to measure thermal resistance of a closed loop pulsating heat pipe (CLPHP) having five turns, and the preparation method of Al<subscript>2</subscript>O<subscript>3</subscript> (Aluminium Oxide) nanoparticles are also presented. The working fluids in the present work are DI (deionised) water and Al<subscript>2</subscript>O<subscript>3</subscript>/DI nanofluid with a surfactant, and experiments are performed for different filling ratios of the working fluid in the CLPHP. The variation of thermal resistance of CLPHP with pressure and time are presented and discussed. It is observed that the thermal resistance was minimum with 60% of filling ratio of Al<subscript>2</subscript>O<subscript>3</subscript>/DI water nanofluid. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
2960
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
174637032
Full Text :
https://doi.org/10.1063/5.0183494