Back to Search
Start Over
Assessment of Cataract Risk after Diagnostic Head CT Scan Radiation Exposure in Ontario, Canada.
- Source :
- Radiation Research; Jan2024, Vol. 201 Issue 1, p1-6, 6p
- Publication Year :
- 2024
-
Abstract
- Ionizing radiation is one of the known risk factors for cataract development, however, there is still debate regarding the level of risk after low dose exposures. One of the largest sources of radiation exposure to the lens of the eye is diagnostic CT scans. The aim of this study was to examine whether ionizing radiation associated with head CT scans increases cataract risk in residents of Ontario, Canada. Data were collected from January 1, 1994 to December 31, 2015 (22 years) from anonymized Ontario Health Insurance Plan (OHIP) medical records for over 16 million subjects. A lens dose was estimated for each CT scan using the National Cancer Institute dosimetry system for CT (NCICT) program combined with Canada-specific CTDI<subscript>vol</subscript> data. Multivariate Cox proportional hazards analysis was performed with cataract extraction surgery as the primary outcome and lens dose as the main variable of interest, with inclusion of various medical and demographic covariates. Lag periods of 3, 5 and 7 years were incorporated. When lens dose was treated as a continuous variable, hazard ratios (per 100 mGy) ranged from 0.82 (0.80–0.84) to 1.10 (1.09–1.11) depending on the lag period. As a secondary analysis, when individuals were binned based on their total cumulative dose, no significant dose response pattern was observed in the low dose region. Overall, within the bounds of this study, the data do not support an increased risk of vision impairing cataracts after diagnostic head CT scan radiation exposure. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00337587
- Volume :
- 201
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Radiation Research
- Publication Type :
- Academic Journal
- Accession number :
- 174814708
- Full Text :
- https://doi.org/10.1667/RADE-23-00179.1