Efficiency of a Modular Cleanroom for Space Applications.
- Source :
- Fluid Dynamics & Materials Processing; 2024, Vol. 20 Issue 3, p547-562, 16p
- Publication Year :
- 2024
-
Abstract
- A prototype cleanroom for hazardous testing and handling of satellites prior to launcher encapsulation, satisfying the ISO8 standard has been designed and analyzed in terms of performances. Unsteady Reynolds Averaged Navier-Stokes (URANS) models have been used to study the related flow field and particulate matter (PM) dispersion. The outcomes of the URANS models have been validated through comparison with equivalent large-eddy simulations. Special attention has been paid to the location and shape of the air intakes and their orientation in space, in order to balance the PM convection and diffusion inside the cleanroom. Forming a cyclone-type flow pattern inside the cleanroom is a key to maintaining a high ventilation efficiency. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 1555256X
- Volume :
- 20
- Issue :
- 3
- Database :
- Complementary Index
- Journal :
- Fluid Dynamics & Materials Processing
- Publication Type :
- Academic Journal
- Accession number :
- 174906280
- Full Text :
- https://doi.org/10.32604/fdmp.2023.028601