Back to Search Start Over

Quantifying neutrophil extracellular trap release in a combined infection–inflammation NET-array device.

Authors :
Datla, Udaya Sree
Vundurthy, Bhaskar
Hook, Jessica S.
Menon, Nidhi
Razmi Bagtash, Hossein
Shihabeddin, Tarik
Schmidtke, David W.
Moreland, Jessica G.
Radic, Marko Z.
Jones, Caroline N.
Source :
Lab on a Chip; 2/7/2024, Vol. 24 Issue 3, p615-628, 14p
Publication Year :
2024

Abstract

Excessive release of neutrophil extracellular traps (NETs) has been reported in various human pathologies, including COVID-19 patients. Elevated NET levels serve as a biomarker, indicating increased coagulopathy and immunothrombosis risks in these patients. Traditional immunoassays employed to quantify NET release focus on bulk measurements of released chromatin in simplified microenvironments. In this study, we fabricated a novel NET-array device to quantify NET release from primary human neutrophils with single-cell resolution in the presence of the motile bacteria Pseudomonas aeruginosa PAO1 and inflammatory mediators. The device was engineered to have wide chambers and constricted loops to measure NET release in variably confined spaces. Our open NET-array device enabled immunofluorescent labeling of citrullinated histone H3, a NET release marker. We took time-lapse images of primary healthy human neutrophils releasing NETs in clinically relevant infection and inflammation-rich microenvironments. We then developed a computer-vision-based image processing method to automate the quantification of individual NETs. We showed a significant increase in NET release to Pseudomonas aeruginosa PAO1 when challenged with inflammatory mediators tumor necrosis factor-α [20 ng mL<superscript>−1</superscript>] and interleukin-6 [50 ng mL<superscript>−1</superscript>], but not leukotriene B<subscript>4</subscript> [20 nM], compared to the infection alone. We also quantified the temporal dynamics of NET release and differences in the relative areas of NETs, showing a high percentage of variable size NET release with combined PAO1 – inflammatory mediator treatment, in the device chambers. Importantly, we demonstrated reduced NET release in the confined loops of our combined infection–inflammation microsystem. Ultimately, our NET-array device stands as a valuable tool, facilitating experiments that enhance our comprehension of the spatiotemporal dynamics of NET release in response to infection within a defined microenvironment. In the future, our system can be used for high throughput and cost-effective screening of novel immunotherapies on human neutrophils in view of the importance of fine-tuning NET release in controlling pathological neutrophil-driven inflammation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14730197
Volume :
24
Issue :
3
Database :
Complementary Index
Journal :
Lab on a Chip
Publication Type :
Academic Journal
Accession number :
175142270
Full Text :
https://doi.org/10.1039/d3lc00648d