Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report.
Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report.
- Source :
- Journal of Cardiothoracic Surgery; 2/6/2024, Vol. 19 Issue 1, p1-5, 5p
- Publication Year :
- 2024
-
Abstract
- Background: Electrical storm (ES) is a clinical emergency characterized by multiple malignant ventricular arrhythmias or ICD discharges within 24 h, requiring early rational management. Case presentation: We report a 55-year-old man who underwent aortic valve replacement experienced recurrent ventricular tachycardia/ventricular fibrillation. A temporary permanent pacemaker with the EnSite system was implanted, and significant inhibition of the electrical storm, attributed to the atrial overdrive pacing, ensued. Conclusions: In emergency regarding an electrical storm, the bedside temporary permanent pacemaker implantation with the EnSite system is concluded to be feasible and safe. [ABSTRACT FROM AUTHOR]