Back to Search Start Over

Hemodynamic study on the therapeutic effects of varying diameter embolic coils in the treatment of intracranial aneurysms.

Authors :
Ren, Xiaoyu
Li, Haoran
Xu, Kaihang
Li, Zhongkai
Gao, Bin
Lu, Wangsheng
Yang, Guangming
Wang, Yunjie
Yin, Yin
Chen, Tao
Source :
International Journal for Numerical Methods in Biomedical Engineering; Mar2024, Vol. 40 Issue 3, p1-18, 18p
Publication Year :
2024

Abstract

Endovascular coiling is the predominant method for treating cerebral aneurysms. Extensive reports on selecting coil length, hardness, and material are available. However, the impact of coil diameter on postoperative outcomes remains unclear. This study enrolled six personalized geometric models of intracranial aneurysms: three bifurcation aneurysms and three sidewall aneurysms. Four coil models were constructed by changing the coil diameter. Coil embolization was simulated using the finite element method. Computational fluid dynamics was used to characterize hemodynamics in the aneurysms after embolization. Evaluation parameters included velocity reduction, wall shear stress (WSS), low WSS (LWSS), oscillatory shear index (OSI), relative residence time (RRT), and residual flow volume in the aneurysms. At the peak time (t = 0.17 s), the proportion of LWSS area in bifurcation aneurysms increase with the rise in coil diameter: 0.8D, 71.28 ± 12.62% versus 1D, 74.97 ± 19.17% versus 1.2D, 78.88 ± 18.56% versus 1.4D, 84.00 ± 11.53% (mean ± SD). The proportion of high OSI area decreases as the coil diameter increases: 0.8D, 4.41% ± 2.82% versus 1.0D, 3.78 ± 3.33% versus 1.2D, 2.28% ± 1.77% versus 1.4D, 1.58% ± 1.11% (mean ± SD). The proportion of high RRT area increases as the coil diameter rises: 0.8D, 3.40% ± 1.68% versus 1.0D, 7.67 ± 4.12% versus 1.2D, 9.84% ± 9.50% versus 1.4D, 22.29% ± 14.28% (mean ± SD). Side wall aneurysms do not exhibit the aforementioned trend. Bifurcation aneurysms plugged with a coil of 1.4 times the diameter have the largest RFVs (<10 mm/s) within the group. Aforementioned patterns are not found in sidewall aneurysms. In the treatment of aneurysms with coiling, varying coil diameters can result in different hemodynamic environments within the aneurysm. Larger coil diameters have improved hemodynamic performance for bifurcation aneurysms. However, coil diameter and embolization effectiveness have no significant relationship for sidewall aneurysms. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20407939
Volume :
40
Issue :
3
Database :
Complementary Index
Journal :
International Journal for Numerical Methods in Biomedical Engineering
Publication Type :
Academic Journal
Accession number :
175826698
Full Text :
https://doi.org/10.1002/cnm.3807