Back to Search Start Over

Free‐Breathing Compressed Sensing Cine Cardiac MRI for Assessment of Left Ventricular Strain by Feature Tracking in Children.

Authors :
Xu, Ke
Xu, Rong
Xu, Hua‐yan
Xie, Lin‐jun
Yang, Zhi‐gang
Fu, Hang
Bai, Wei
Zhang, Lu
Zhou, Xiao‐yue
Guo, Ying‐kun
Source :
Journal of Magnetic Resonance Imaging; May2024, Vol. 59 Issue 5, p1832-1840, 9p
Publication Year :
2024

Abstract

Background: Cardiac MRI feature‐tracking (FT) with breath‐holding (BH) cine balanced steady state free precession (bSSFP) imaging is well established. It is unclear whether FT‐strain measurements can be reliably derived from free‐breathing (FB) compressed sensing (CS) bSSFP imaging. Purpose: To compare left ventricular (LV) strain analysis and image quality of an FB CS bSSFP cine sequence with that of a conventional BH bSSFP sequence in children. Study Type: Prospective. Subjects: 40 children able to perform BHs (cohort 1 [12.1 ± 2.2 years]) and 17 children unable to perform BHs (cohort 2 [5.2 ± 1.8 years]). Field Strength/Sequence: 3T, bSSFP sequence with and without CS. Assessment: Acquisition times and image quality were assessed. LV myocardial deformation parameters were compared between BH cine and FB CS cine studies in cohort 1. Strain indices and image quality of FB CS cine studies were also assessed in cohort 2. Intraobserver and interobserver variability of strain parameters was determined. Statistical Tests: Paired t‐test, Wilcoxon signed‐rank test, intraclass correlation coefficient (ICC), and Bland–Altman analysis. A P‐value <0.05 was considered statistically significant. Results: In cohort 1, the mean acquisition time of the FB CS cine study was significantly lower than for conventional BH cine study (15.6 s vs. 209.4 s). No significant difference were found in global circumferential strain rate (P = 0.089), global longitudinal strain rate (P = 0.366) and EuroCMR image quality scores (P = 0.128) between BH and FB sequences in cohort 1. The overall image quality score of FB CS cine in cohort 2 was 3.5 ± 0.5 with acquisition time of 14.7 ± 2.1 s. Interobserver and intraobserver variabilities were good to excellent (ICC = 0.810 to 0.943). Data Conclusion: FB CS cine imaging may be a promising alternative technique for strain assessment in pediatric patients with poor BH ability. Level of Evidence: 1 Technical Efficacy: Stage 1 [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10531807
Volume :
59
Issue :
5
Database :
Complementary Index
Journal :
Journal of Magnetic Resonance Imaging
Publication Type :
Academic Journal
Accession number :
176473961
Full Text :
https://doi.org/10.1002/jmri.29003