Back to Search Start Over

Activated rate-response is associated with increased mortality risk in cardiac device carriers with acute heart failure.

Authors :
Huttelmaier, Moritz T.
Münsterer, Sascha
Morbach, Caroline
Sahiti, Floran
Scholz, Nina
Albert, Judith
Gabel, Alexander
Angermann, Christiane
Ertl, Georg
Frantz, Stefan
Störk, Stefan
Fischer, Thomas H.
Source :
PLoS ONE; 4/18/2024, Vol. 19 Issue 4, p1-17, 17p
Publication Year :
2024

Abstract

Aims: This study investigated whether an activated R-mode in patients carrying a cardiac implantable electronic device (CIED) is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). Methods: Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and follows patients admitted for AHF were studied. We compared CIED carriers with activated R-mode stimulation (CIED-R) to CIED carriers not in R-mode (CIED-0) and patients without CIEDs (no-CIED). The independent impact of R-mode activation on 12-month all-cause death was examined using uni- and multivariable Cox proportional hazards regression taking into account potential confounders, and hazard ratios (HR) with their 95% confidence intervals (CI) were reported. Results: Mean heart rate on admission was lower in CIED-R (n = 37, 16% women) vs. CIED-0 (n = 64, 23% women) or no-CIED (n = 511, 43% women): 70 bpm vs. 80 bpm or 82 bpm; both p<0.001. In-hospital mortality was similar across groups, but age- and sex-adjusted all-cause 12-month mortality risk was differentially affected by R-mode activation; CIED-R vs. CIED-0: HR 2.44, 95%CI 1.25–4.74; CIED-R vs. no-CIED: HR 2.61, 95%CI 1.59–4.29. These effects persisted after multivariable adjustment for potential confounders. Within CIED-R, mortality risk was similar in patients with pacemakers vs. ICDs and in subgroups with left ventricular ejection fraction (LVEF) <50% vs. ≥50%. Conclusion: In patients admitted with AHF, R-mode stimulation was associated with a significantly increased 12-month mortality risk. Our findings shed new light on "admission heart rate" as a potentially treatable target in AHF. Our data are compatible with the concept that chronotropic incompetence contributes to an adverse outcome in these patients and may not be adequately treated through accelerometer-based R-mode stimulation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
19
Issue :
4
Database :
Complementary Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
176685059
Full Text :
https://doi.org/10.1371/journal.pone.0302321