Back to Search Start Over

Hybrid optimal-FOPID based UPQC for reducing harmonics and compensate load power in renewable energy sources grid connected system.

Authors :
Devi, T. Anuradha
Rao, G. Srinivasa
Kumar, T. Anil
Goud, B. Srikanth
Rami Reddy, Ch.
Eutyche, Mbadjoun Wapet Daniel
Aymen, Flah
El-Bayedh, Claude Ziad
Kraiem, Habib
Blazek, Vojtech
Source :
PLoS ONE; 5/14/2024, Vol. 19 Issue 5, p1-53, 53p
Publication Year :
2024

Abstract

Integration of renewable energy sources (RES) to the grid in today's electrical system is being encouraged to meet the increase in demand of electrical power and also overcome the environmental related problems by reducing the usage of fossil fuels. Power Quality (PQ) is a critical problem that could have an effect on utilities and consumers. PQ issues in the modern electric power system were turned on by a linkage of RES, smart grid technologies and widespread usage of power electronics equipment. Unified Power Quality Conditioner (UPQC) is widely employed for solving issues with the distribution grid caused by anomalous voltage, current, or frequency. To enhance UPQC performance, Fractional Order Proportional Integral Derivative (FOPID) is developed; nevertheless, a number of tuning parameters restricts its performance. The best solution for the FOPID controller problem is found by using a Coati Optimization Algorithm (COA) and Osprey Optimization Algorithm (OOA) are combined to make a hybrid optimization CO-OA algorithm approach to mitigate these problems. This paper proposes an improved FOPID controller to reduce PQ problems while taking load power into account. In the suggested model, a RES is connected to the grid system to supply the necessary load demand during the PQ problems period. Through the use of an enhanced FOPID controller, both current and voltage PQ concerns are separately modified. The pulse signal of UPQC was done using the optimal controller, which analyzes the error value of reference value and actual value to generate pulses. The integrated design mitigates PQ issues in a system at non-linear load and linear load conditions. The proposed model provides THD of 12.15% and 0.82% at the sag period, 10.18% and 0.48% at the swell period, and 10.07% and 1.01% at the interruption period of non-linear load condition. A comparison between the FOPID controller and the traditional PI controller was additionally taken. The results showed that the recommended improved FOPID controller for UPQC has been successful in reducing the PQ challenges in the grid-connected RESs system. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
19
Issue :
5
Database :
Complementary Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
177216415
Full Text :
https://doi.org/10.1371/journal.pone.0300145