Back to Search Start Over

Chemical oxygen demand and tannin/lignin removal from paper mill wastewater by electrocoagulation combined with peroxide and hypochlorite treatments.

Authors :
Caglak, Abdulkadir
Sari-Erkan, Hanife
Onkal Engin, Guleda
Source :
Environmental Technology; Jun2024, Vol. 45 Issue 15, p3076-3094, 19p
Publication Year :
2024

Abstract

The present investigation sought to assess the practicality of utilizing a combined pre-treatment approach comprising electrocoagulation, peroxide, and hypochlorite treatments for the removal of chemical oxygen demand (COD) and tannin/lignin from paper mill wastewater. The study aimed to optimize the operating parameters with a view to maximizing the removal efficiencies while minimizing energy consumption. A pair of iron electrodes were used as anode and cathode in the study, and the main operating parameters were determined as initial pH, applied current, treatment time and oxidant dosage/COD ratio. Response surface methodology (RSM) was used to evaluate the effect of these parameters on COD and tannin/lignin removals. The primary findings of the investigation indicated that the integration of electrocoagulation with peroxide and hypochlorite treatments exhibited efficacy in removing COD, tannin/lignin, colour, phenol, and turbidity from paper mill wastewater. The optimized conditions resulted in COD removal efficiencies of 48.13 ± 2.2% and 29.53 ± 1.4% for EC with H<subscript>2</subscript>O<subscript>2</subscript> and Ca(OCl)<subscript>2</subscript>, respectively. Tannin/lignin removal efficiencies were 92.59 ± 3.6% and 94.09 ± 1.8% for EC-H<subscript>2</subscript>O<subscript>2</subscript> and EC-Ca(OCl)<subscript>2</subscript>, respectively. The specific energy consumption (SEC) values showed that EC-Ca(OCl)<subscript>2</subscript> required 7 times more energy than EC-H<subscript>2</subscript>O<subscript>2</subscript> for removing 1 kg COD. The principal deduction drawn from the study was that EC-H<subscript>2</subscript>O<subscript>2</subscript> pre-treatment demonstrated superior COD removal efficiency and lower energy consumption, while EC-Ca(OCl)<subscript>2</subscript> pre-treatment exhibited greater efficiency in removing toxic and recalcitrant pollutants. In future studies, it would be useful to conduct research to increase COD removal efficiency in addition to tannin/lignin removal in EC-Ca(OCl)<subscript>2</subscript> process. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09593330
Volume :
45
Issue :
15
Database :
Complementary Index
Journal :
Environmental Technology
Publication Type :
Academic Journal
Accession number :
177338292
Full Text :
https://doi.org/10.1080/09593330.2023.2206529