Back to Search Start Over

Analysis of ICH-Q3D Endorsed Elemental Impurities in Macrolide Antibiotics by ICP-MS.

Authors :
Mathesan, Ravisankar
Sekar, Alexandar
Raju, Senthil Kumar
Mohan, Kumar
Sri, Venkateswarlu Bendi
Source :
Indian Journal of Pharmaceutical Education & Research; Oct-Dec2023, Vol. 57 Issue 4, p1219-1225, 7p
Publication Year :
2023

Abstract

Aim: The objective of this study was to determine the amount of twenty-three elemental impurities in Azithromycin API. A rapid, selective, precise, accurate and sensitive approach for detecting elemental impurities in Azithromycin API was developed and validated using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Background: Conventional analytical methods used in pharmacopoeia's are less sensitive and accurate to detect heavy metal impurities. Concerning this issue, a new inductively coupled plasma mass spectrometry-based method was developed and validated as a different choice to investigate the Elemental impurities in an Azithromycin API sample. Materials and Methods: In the present research work, test samples were prepared with microwave supported acid digestion. Results: After a sequence of trails, the mixture of nitric acid, hydrochloric acid, and hydrogen peroxide (4 mL: 1 mL: 0.5 mL) with the accepted recovery range was chosen for the Azithromycin API's digestion. Conclusion: According to ICH and USP 233 guidelines, the proposed technique was successfully validated using ICP-MS for linearity, precision, accuracy, LOD, LOQ, and ruggedness. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00195464
Volume :
57
Issue :
4
Database :
Complementary Index
Journal :
Indian Journal of Pharmaceutical Education & Research
Publication Type :
Academic Journal
Accession number :
177445803
Full Text :
https://doi.org/10.5530/ijper.57.4.145