Back to Search Start Over

Suppression Behavior Difference Between Compressed Air/Nitrogen Foam over Liquid Fuel Surface Under Constant Radiation Heat Flux.

Authors :
Tian, Fengyuan
Wang, Kun
Fang, Jun
Shah, Hassan Raza
Lang, Xuqing
Mu, Shanjun
Wang, Jinjun
Wang, Jingwu
Source :
Fire Technology; Mar2024, Vol. 60 Issue 2, p1225-1243, 19p
Publication Year :
2024

Abstract

Compressed air foam (CAF) and compressed nitrogen foam (CNF) have been widely used for storage tank fire suppression, benefiting from their highly effective extinguishing performance. Mass loss rate is an important parameter to evaluate the stability of foam and an important factor to influence the suppression efficiency of foam. In this work, mass loss mechanisms including drainage and evaporation of two types of foams under a fixed radiation source were experimentally studied to reflect the foam fire suppression efficiency. It was observed that the foam drain rate is directly proportional to the foam mass, with a slight relation to the irradiance when irradiance is lower than 20 kW/m<superscript>2</superscript>. Once the irradiance reaches 30 kW/m<superscript>2</superscript>, the drain rate increases significantly. For evaporation, as expected from the established theoretical model, the evaporation rate shows a positive relationship with the irradiance level. However, there is no relationship between foam evaporation rate and the initial foam thickness. Through the experimentally measured evaporation rate, the average foam absorptivity is calculated to be approximately 0.63 ± 0.07 for both foams at an expansion ratio (ER) of 10. A comparative analysis of mass loss characteristics in the two types of foam was also undertaken. It was found that the two types of foam have distinct drain rates due to their different foam stability caused by the different expanded gas properties. However, they have a similar evaporation rate. In addition, the foam destruction rate and time to ignite the underlying fuel were measured, and a linear relationship between ignition time and initial foam height was found with a slope of 1.7 ± 0.2. The results demonstrate that CNF has a better fire suppression efficiency, which can be attributed to the better stability of the foam and the nitrogen released by broken bubbles, which inhibits ignition. The work presented here reveals the different functional mechanisms of compressed air/nitrogen foam and presents useful information that could enhance our understanding of the fire suppression effects of fire extinguishing foam. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00152684
Volume :
60
Issue :
2
Database :
Complementary Index
Journal :
Fire Technology
Publication Type :
Academic Journal
Accession number :
177625254
Full Text :
https://doi.org/10.1007/s10694-022-01332-0