Back to Search Start Over

Does concordance between preoperatively measured prostate volume and enucleated weight predict outcomes in endoscopic enucleation of the prostate? Results from the REAP database.

Authors :
Fong, Khi Yung
Gauhar, Vineet
Castellani, Daniele
Lim, Ee Jean
Sofer, Mario
Enikeev, Dmitry
Sancha, Fernando Gómez
Teoh, Jeremy
Somani, Bhaskar
Herrmann, Thomas
Source :
World Journal of Urology; 8/7/2024, Vol. 42 Issue 1, p1-8, 8p
Publication Year :
2024

Abstract

Background: We aimed to determine if preoperative prostate volume-enucleated weight concordance predicts short-term anatomical endoscopic enucleation of the prostate (AEEP) outcomes using the REAP international database. Methods: 649 patients with data on both preoperative ultrasound-derived prostate volume and enucleated specimen weight were analyzed. Linear regression was used to investigate the effect of volume-weight concordance on postoperative outcomes. Model residuals were used to divide the cohort into 3 centiles: (1) less-than-expected enucleated specimen weight; (2) appropriate concordance between prostate volume and specimen weight; (3) more-than-expected specimen weight. Outcomes were also analyzed with only enucleated weight as a predictor (comparing ≤ 80 g and > 80 g). Results: There was a trend towards more-than-expected enucleated specimen weight with increased age (p = 0.006). There was an increasing trend of operation time (p = 0.012) and enucleation time (p = 0.015) as specimen weight increased, and a decreasing trend of postoperative acute urinary retention (p = 0.005). Laser type, enucleation method, and early apical release were similar. In correlation analysis, greater-than-expected prostate weight was associated with greater Qmax improvement at 3 months. Prostate weight alone did not appear to be a significant predictor of outcomes. Conclusions: If enucleated specimen weight is more than expected according to preoperative ultrasound volume measurement, greater Qmax improvement and less postoperative acute urinary retention is expected. Although precision may be limited by ultrasound approximation and inexact specimen weight measurements, these shortcomings are similar in real-world clinical practice. Overall, preoperative prostate volume and actual enucleated specimen weight should be interpreted in the context of each other to predict clinical outcomes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07244983
Volume :
42
Issue :
1
Database :
Complementary Index
Journal :
World Journal of Urology
Publication Type :
Academic Journal
Accession number :
178878459
Full Text :
https://doi.org/10.1007/s00345-024-05194-9