Back to Search
Start Over
The use of accelerometers to improve estimation of the thermic effect of food in whole room calorimetry studies.
- Source :
- Journal of Applied Physiology; Jul2024, Vol. 137 Issue 1, p1-9, 9p
- Publication Year :
- 2024
-
Abstract
- We tested whether spontaneous physical activity (SPA) from accelerometers could be used in a whole room calorimeter to estimate thermic effect of food (TEF). Eleven healthy participants (n = 7 females; age: 27 ± 4 yr; body mass index: 22.8 ± 2.6 kg/m<superscript>2</superscript>) completed two 23-h visits in randomized order: one "fed" with meals provided and one "fasted" with no food. SPA was measured by ActivPAL and Actigraph accelerometers. Criterion TEF was calculated as the difference in total daily energy expenditure (TDEE) between fed and fasted visits and compared with three methods of estimating TEF: 1) SPA-adjusted TEF (adjTEF)—difference in TDEE without SPA between visits, 2) Wakeful TEF—difference in energy expenditure obtained from linear regression and basal metabolic rate during waking hours, 3) 24-h TEF—increase in TDEE above SPA and sleeping metabolic rate. Criterion TEF was 9.4 ± 4.5% of TDEE. AdjTEF (difference in estimated vs. criterion TEF: activPAL: −0.3 ± 3.3%; Actigraph: −1.8 ± 8.0%) and wakeful TEF (activPAL: −0.9 ± 6.1%; Actigraph: −2.8 ± 7.6%) derived from both accelerometers did not differ from criterion TEF (all P > 0.05). ActivPAL-derived 24-h TEF overestimated TEF (6.8 ± 5.4%, P = 0.002), whereas Actigraph-derived 24-h TEF was not significantly different (4.3 ± 9.4%, P = 0.156). TEF estimations using activPAL tended to show better individual-level agreement (i.e., smaller coefficients of variation). Both accelerometers can be used to estimate TEF in a whole room calorimeter; wakeful TEF using activPAL is the most viable option given strong group-level accuracy and reasonable individual agreement. NEW & NOTEWORTHY: Two research-grade accelerometers can effectively estimate spontaneous physical activity and improve the estimation of thermic effect of food (TEF) in whole room calorimeters. The activPAL demonstrates strong group-level accuracy and reasonable individual-level agreement in estimating wakeful TEF, whereas a hip-worn Actigraph is an acceptable approach for estimating 24-h TEF. These results highlight the promising potential of accelerometers in advancing energy balance research by improving the assessment of TEF within whole room calorimeters. [ABSTRACT FROM AUTHOR]
- Subjects :
- BASAL metabolism
ACCELEROMETERS
CALORIMETRY
BODY mass index
TEFF
Subjects
Details
- Language :
- English
- ISSN :
- 87507587
- Volume :
- 137
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Journal of Applied Physiology
- Publication Type :
- Academic Journal
- Accession number :
- 178914861
- Full Text :
- https://doi.org/10.1152/japplphysiol.00763.2023