Back to Search Start Over

Evaluation of a multi-objective model for pulsed heat pipe performance.

Authors :
Bhattad, Atul
Atgur, Vinay
Boggarapu, Nageswara Rao
Banapurmath, N. R.
Badruddin, Irfan Anjum
Sajjan, Ashok M.
Alqahtani, Mohammed
Kamangar, Sarfaraz
Vadlamudi, Chandramouli
Krishnappa, Sanjay
Source :
Journal of Thermal Analysis & Calorimetry; Jul2024, Vol. 149 Issue 14, p7621-7633, 13p
Publication Year :
2024

Abstract

Pulsating heat pipes (PHPs) offer a promising solution for thermal management in diverse industries owing to their simplicity, cost-effectiveness, and impressive cooling capabilities. The angle of inclination of the heat pipe with reference to the horizontal plane significantly influences PHP performance. Unsatisfactory outcomes were observed at 90° and 180° inclination angles. A comprehensive investigation explored the impact of tilt angle and fill ratio on PHP performance indicators, specifically heat transfer rate (HTR), overall heat transfer coefficient (OHTC), and thermal resistance (TR). Tilt angles ranged from 30° to 60°, while fill ratios varied from 40 to 80%. To optimize PHP working parameters that maximize HTR, minimize TR, and enhance OHTC, a modified Taguchi approach was integrated with a robust multi-objective optimization technique. Empirical models for HTR, TR, and OHTC were developed and validated against experimental data. The recommended PHP working parameters are a 60% fill ratio and a 30° tilt angle. For the optimal parameters, HTR estimates ranged from 33.96 to 34.29 W, with the experimental value of 34.124 W falling within this range. TR estimates ranged from 0.0207 to 0.1097 °C W<superscript>−1</superscript>, encompassing the experimental value of 0.078 °C W<superscript>−1</superscript>. OHTC estimates varied between 835.8 and 958.42 W m<superscript>−2</superscript> K<superscript>−1</superscript>, including the experimental value of 835.79 W m<superscript>−2</superscript> K<superscript>−1</superscript>. The developed empirical relationships provide valuable insights into PHP performance for any fill ratio and tilt angle within the applicable range. PHPs find diverse applications in refrigeration, aerospace, waste heat recovery, and the utilization of low-grade energy. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13886150
Volume :
149
Issue :
14
Database :
Complementary Index
Journal :
Journal of Thermal Analysis & Calorimetry
Publication Type :
Academic Journal
Accession number :
179069209
Full Text :
https://doi.org/10.1007/s10973-024-13313-2