Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom.

Authors :
Wassenaar, Nienke P. M.
Gurney‐Champion, Oliver J.
van Schelt, Anne‐Sophie
Bruijnen, Tom
van Laarhoven, Hanneke W. M.
Stoker, Jaap
Nederveen, Aart J.
Runge, Jurgen H.
Schrauben, Eric M.
Source :
Magnetic Resonance in Medicine; Nov2024, Vol. 92 Issue 5, p2051-2064, 14p
Publication Year :
2024

Abstract

Purpose: For reliable DCE MRI parameter estimation, k‐space undersampling is essential to meet resolution, coverage, and signal‐to‐noise requirements. Pseudo‐spiral (PS) sampling achieves this by sampling k‐space on a Cartesian grid following a spiral trajectory. The goal was to optimize PS k‐space sampling patterns for abdomin al DCE MRI. Methods: The optimal PS k‐space sampling pattern was determined using an anthropomorphic digital phantom. Contrast agent inflow was simulated in the liver, spleen, pancreas, and pancreatic ductal adenocarcinoma (PDAC). A total of 704 variable sampling and reconstruction approaches were created using three algorithms using different parametrizations to control sampling density, halfscan and compressed sensing regularization. The sampling patterns were evaluated based on image quality scores and the accuracy and precision of the DCE pharmacokinetic parameters. The best and worst strategies were assessed in vivo in five healthy volunteers without contrast agent administration. The best strategy was tested in a DCE scan of a PDAC patient. Results: The best PS reconstruction was found to be PS‐diffuse based, with quadratic distribution of readouts on a spiral, without random shuffling, halfscan factor of 0.8, and total variation regularization of 0.05 in the spatial and temporal domains. The best scoring strategy showed sharper images with less prominent artifacts in healthy volunteers compared to the worst strategy. Our suggested DCE sampling strategy also showed high quality DCE images in the PDAC patient. Conclusion: Using an anthropomorphic digital phantom, we identified an optimal PS sampling strategy for abdominal DCE MRI, and demonstrated feasibility in a PDAC patient. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07403194
Volume :
92
Issue :
5
Database :
Complementary Index
Journal :
Magnetic Resonance in Medicine
Publication Type :
Academic Journal
Accession number :
179169174
Full Text :
https://doi.org/10.1002/mrm.30213