Co-Deposition of Bimetallic Au-Pt with L-Cysteine on Electrodes and Removal of Copper by Iron Powder for Trace Aqueous Arsenic Detection.
- Source :
- Journal of Composites Science; Aug2024, Vol. 8 Issue 8, p327, 12p
- Publication Year :
- 2024
-
Abstract
- Much progress has been made in the determination of As (III), while numerous electrochemical sensors based on metal nanomaterials with significant sensitivity and precision have been developed. However, further research is still required to achieve rapid detection and avoid interference from other metal ions (especially copper ions). In this study, bimetallic AuPt nanoparticles are electrochemically modified with screen printing electrodes. What's more, L-cysteine also self-assembles with AuNPs through Au-S bond to enhance the electrochemical performance. To overcome the interference of Cu (II) in the sensing process, the reduced iron powder was chosen to remove Cu (II) and other oxidizing organics in aqueous solutions. The lowest detectable amount is 0.139 ppb, a linear range of 1~50 ppb with superlative stability by differential pulse anodic stripping voltammetry. Fortunately, the reduced iron powder could eliminate the Cu (II) with no effect on the As (III) signal. [ABSTRACT FROM AUTHOR]