Back to Search Start Over

Performance Evaluation of CO 2 + SiCl 4 Binary Mixture in Recompression Brayton Cycle for Warm Climates.

Authors :
Siddiqui, Muhammad Ehtisham
Almitani, Khalid H.
Source :
Processes; Oct2024, Vol. 12 Issue 10, p2155, 12p
Publication Year :
2024

Abstract

This work demonstrates the potential of CO<subscript>2</subscript> + SiCl<subscript>4</subscript> binary mixture as a working fluid for power generation cycle. Recompression Brayton cycle configuration is considered due to its proven record of high performance for medium- to high-temperature sources. The objective of this study is to assess the thermodynamic performance of a recompression Brayton cycle using a CO<subscript>2</subscript> + SiCl<subscript>4</subscript> binary mixture as a working fluid, particularly under warm climate conditions. The cycle is simulated using the Peng–Robinson equation of state in Aspen Hysys (v11) software, and the model is validated by comparing VLE data against experimental data from the literature. The analysis involves the assessment of cycle's thermal efficiency and exergy efficiency under warm climatic conditions, with a minimum cycle temperature of 40 °C. The results demonstrate a notable improvement in the cycle's thermodynamic performance with CO<subscript>2</subscript> + SiCl<subscript>4</subscript> binary mixture compared to pure CO<subscript>2</subscript>. A small concentration (5%) of SiCl<subscript>4</subscript> in CO<subscript>2</subscript> increases the thermal efficiency of the cycle from 41.7% to 43.4%. Moreover, irreversibility losses in the cooler and the heat recovery unit are significantly lower with the CO<subscript>2</subscript> + SiCl<subscript>4</subscript> binary mixture than with pure CO<subscript>2</subscript>. This improvement enhances the overall exergy efficiency of the cycle, increasing it from 62.1% to 70.2%. The primary reason for this enhancement is the substantial reduction in irreversibility losses in both the cooler and the HTR. This study reveals that when using a CO<subscript>2</subscript> + SiCl<subscript>4</subscript> mixture, the concentration must be optimized to avoid condensation in the compressor, which can cause physical damage to the compressor blades and other components, as well as increase power input. This issue arises from the higher glide temperature of the mixture at increased SiCl<subscript>4</subscript> concentrations and the limited heat recovery from the cycle. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
22279717
Volume :
12
Issue :
10
Database :
Complementary Index
Journal :
Processes
Publication Type :
Academic Journal
Accession number :
180526578
Full Text :
https://doi.org/10.3390/pr12102155