Back to Search
Start Over
Accurate Embolization for Endoleak after F-TEVAR of Thoracic Aortic Dissection by Detachable Coils.
- Source :
- Vascular; Dec2024, Vol. 32 Issue 6, p1378-1384, 7p
- Publication Year :
- 2024
-
Abstract
- Objectives: To evaluate the efficacy and clinical outcomes of accurate embolization of endoleaks after fenestrated thoracic endovascular aortic repair (F-TEVAR) for thoracic aortic dissections. Methods: Twenty patients with endoleaks (17 type I and 3 type II) after fenestrated thoracic endovascular aortic repair (F-TEVAR) were embolized using detachable and ordinary coils. We assessed the success rate and complications of the operation, and its effects, through clinical and CT follow-up. Results: The mean clinical follow-up duration was 25.68 ± 11.07 months (3–44 months). During follow-up, all endoleaks were completely embolized and aortic remodeling was improved. Secondary endoleaks occurred in four patients who were embolized twice. No other complications or death were reported. Conclusion: Embolization using detachable and ordinary coils is effective and safe for the treatment of endoleaks after fenestrated thoracic endovascular aortic repair. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 17085381
- Volume :
- 32
- Issue :
- 6
- Database :
- Complementary Index
- Journal :
- Vascular
- Publication Type :
- Academic Journal
- Accession number :
- 181053046
- Full Text :
- https://doi.org/10.1177/17085381231154354