Back to Search Start Over

A VME-Based Readout System for the CMS Preshower Sub-Detector.

Authors :
Antchev, G.
Barney, D.
Bialas, W.
Da Silva, J. C.
Kokkas, P.
Manthos, N.
Reynaud, S.
Sidiropoulos, G.
Snoeys, W.
Vichoudis, P.
Source :
IEEE Transactions on Nuclear Science; Jun2007 Part 2 of 2, Vol. 54 Issue 3, p623-628, 6p
Publication Year :
2007

Abstract

The CMS Preshower is a fine grain detector that comprises 4288 silicon sensors, each containing 32 strips. The raw data are transferred from the detector to the counting room via 1208 optical fibres. Each fibre carries a 600-byte data packet per event. The maximum average level-i trigger rate of 100 kHz results in a total data flow of ~72 GB/s from the Preshower. For the readout of the Preshower, 56 links to the CMS DAQ have been reserved, each having a bandwidth of 200 MB/s (2 kB/event). The total available downstream bandwidth of ~11 GB/s necessitates a reduction in the data volume by a factor of at least 7. A modular VME-based system is currently under development. The main objective of each VME board in this system is to acquire on-detector data from at least 22 optical links, perform on-line data reduction and pass the concentrated data to the CMS DAQ. The principle modules that the system is based on are being developed in collaboration with the TOTEM experiment. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189499
Volume :
54
Issue :
3
Database :
Complementary Index
Journal :
IEEE Transactions on Nuclear Science
Publication Type :
Academic Journal
Accession number :
25575825
Full Text :