Back to Search
Start Over
APPLICATION OF TERAHERTZ RADIATION TO THE DETECTION OF CORROSION UNDER THE SHUTTLE'S THERMAL PROTECTION SYSTEM.
- Source :
- AIP Conference Proceedings; 2/28/2008, Vol. 975 Issue 1, p421-428, 8p, 4 Color Photographs, 1 Black and White Photograph, 4 Diagrams, 1 Graph
- Publication Year :
- 2008
-
Abstract
- There is currently no method for detecting corrosion under Shuttle tiles except for the expensive process of tile removal and replacement; hence NASA is investigating new NDE methods for detecting hidden corrosion. Time domain terahertz radiation has been applied to corrosion detection under tiles in samples ranging from small lab samples to a Shuttle with positive results. Terahertz imaging methods have been able to detect corrosion at thicknesses of 5 mils or greater under 1” thick Shuttle tiles and 7-12 mils or greater under 2” thick Shuttle tiles. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 975
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 31223480
- Full Text :
- https://doi.org/10.1063/1.2902691