Back to Search
Start Over
Symmetric Curvature Patterns for Colonic Polyp Detection.
- Source :
- Medical Image Computing & Computer-Assisted Intervention - MICCAI 2006 (9783540447276); 2006, p169-176, 8p
- Publication Year :
- 2006
-
Abstract
- A novel approach for generating a set of features derived from properties of patterns of curvature is introduced as a part of a computer aided colonic polyp detection system. The resulting sensitivity was 84% with 4.8 false positives per volume on an independent test set of 72 patients (56 polyps). When used in conjunction with other features, it allowed the detection system to reach an overall sensitivity of 94% with a false positive rate of 4.3 per volume. [ABSTRACT FROM AUTHOR]