Back to Search Start Over

IDENTIFICATION OF MODAL DAMPING RATIOS OF FOUR-FLUE CHIMNEY OF A THERMOELECTRICAL PLANT USING PSEUDO-INVERSE MATRIX METHOD.

Authors :
CAVACECE, M.
VALENTINI, R. R.
VITA, L.
Source :
Structural Design of Tall & Special Buildings; Mar2009, Vol. 18 Issue 2, p203-216, 14p, 1 Black and White Photograph, 1 Diagram, 9 Charts, 2 Graphs
Publication Year :
2009

Abstract

Some computational issues related to the identification of modal parameters of structures are presented in this paper. Optimal estimation of modal parameters often requires the solution of an overdetermined linear system of equations. Hence the computation of a pseudo-inverse matrix is involved. In this paper the numerical performance of different algorithms for Moore-Penrose pseudo-inverse computation have been tested for modal analysis of a four-flue chimney of a thermoelectrical plant. The computational scheme herein adopted for parameter identification is based on well-known modal properties and has a fast rate of convergence to solution. The computation of the Rayleigh damping coefficients a and fl is an important step in the area of the modal superposition technique. The proposed approach can accurately predict damping ratios and all the eigenvectors without evaluating mass and stiffness matrices. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15417794
Volume :
18
Issue :
2
Database :
Complementary Index
Journal :
Structural Design of Tall & Special Buildings
Publication Type :
Academic Journal
Accession number :
37197761
Full Text :
https://doi.org/10.1002/tal.405