Limitations of Voltage-Oriented PT Current Control of Grid-Connected PWM Rectifiers With LCL Filters.

Authors :
Dannehi, Joerg
Wessels, Christian
Fuchs, Friedrich Wilhelm
Source :
IEEE Transactions on Industrial Electronics; Feb2009, Vol. 56 Issue 2, p380-388, 9p, 3 Black and White Photographs, 1 Chart, 10 Graphs
Publication Year :
2009

Abstract

Voltage-oriented PI control of three-phase grid- connected pulsewidth-modulation rectifiers with LCL filters is addressed. LCL filters require resonance damping. Active resonance damping is state of the art to face the problem, but it is still under investigation because of the manifold solutions. It is often realized using many sensors and/or complex control algorithms. In contrast, pure PI control requires only one set of current sensors, and its implementation and design are rather simple and well known from the L filter control. PI control has already been shown to be a suitable solution also for LCL filters, but there are limitations. These are investigated in this paper. System stability is analyzed with respect to different ratios of LCL filter resonance and control frequencies. The latter are important parameters for system design and control. Both line and converter current control are analyzed. For a certain range of frequency ratios, the voltage.oriented PI control gives stable performance without additional feedback, but for ratios outside this range, stable operation is impossible. Experimental tests validate the theoretical results. In addition, an experimentally determined LCL filter transfer function is shown in this paper, which shows a lower resonance peak as expected from commonly used filter models. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02780046
Volume :
56
Issue :
2
Database :
Complementary Index
Journal :
IEEE Transactions on Industrial Electronics
Publication Type :
Academic Journal
Accession number :
39366230
Full Text :
https://doi.org/10.1109/TJE.2008.2008774