Back to Search
Start Over
Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan.
- Source :
- Journal of Applied Physics; Jun2010, Vol. 107 Issue 10, p104905-104912, 7p, 3 Color Photographs, 1 Diagram, 3 Charts, 4 Graphs
- Publication Year :
- 2010
-
Abstract
- A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00218979
- Volume :
- 107
- Issue :
- 10
- Database :
- Complementary Index
- Journal :
- Journal of Applied Physics
- Publication Type :
- Academic Journal
- Accession number :
- 51060883
- Full Text :
- https://doi.org/10.1063/1.3392800