Back to Search
Start Over
Control and Implementation of a Matrix-Converter-Based AC Ground Power-Supply Unit for Aircraft Servicing.
- Source :
- IEEE Transactions on Industrial Electronics; Jun2010, Vol. 57 Issue 6, p2076-2084, 9p
- Publication Year :
- 2010
-
Abstract
- This paper deals with the design, control, and implementation of a three-phase ground power-supply unit for aircraft servicing. Instead of a classical back-to-back converter configuration, a three-phase direct ac-ac (matrix) converter has been used as the power conditioning core of the power supply, working in conjunction with input and output LC filters. An optimized control system in the ABC frame employing a repetitive controller has been successfully implemented, taking into account both the transient and steady-state performance targets together with the system effectiveness under extreme unbalanced conditions. Extensive experimental tests on a 7.5-kVA prototype prove the efficiency of the designed system in meeting the high demanding civil and military international standards requirements. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02780046
- Volume :
- 57
- Issue :
- 6
- Database :
- Complementary Index
- Journal :
- IEEE Transactions on Industrial Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 51119177
- Full Text :
- https://doi.org/10.1109/TIE.2009.2034180