Back to Search
Start Over
Treatment of α-Pinene-Contaminated Air Using Silicone Oil-Coated Perlite Biofilter.
- Source :
- Environmental Progress & Sustainable Energy; Oct2010, Vol. 29 Issue 3, p313-318, 6p, 1 Black and White Photograph, 1 Diagram, 4 Graphs
- Publication Year :
- 2010
-
Abstract
- The article describes a study which investigated the use of a perlite biofilter to treat air contaminated with α-pinene. To make the particle surface more hydrophobic, the perlite was coated partially with silicone oil. In comparison to the filter with uncoated perlite, the silicone oil-coated perlite biofilter performed better in removing the air contaminant at 2.5 L/min airflow rate. However, the removal efficiency was almost the same at 1.5 L/min airflow rate. It has been shown that the mass transport of the α-pinene contaminant from gas to liquid is improved by the silicone oil.
- Subjects :
- PERLITE
PINENE
FILTERS & filtration
AIR pollution
AIR flow
SILICONES
Subjects
Details
- Language :
- English
- ISSN :
- 19447442
- Volume :
- 29
- Issue :
- 3
- Database :
- Complementary Index
- Journal :
- Environmental Progress & Sustainable Energy
- Publication Type :
- Academic Journal
- Accession number :
- 54327062
- Full Text :
- https://doi.org/10.1002/ep.10414