Low-Noise Analog ASIC for Silicon and CdTe Sensors.
- Source :
- IEEE Transactions on Nuclear Science; 10/03/2010 Part 3, Vol. 57 Issue 5, p2971-2977, 7p
- Publication Year :
- 2010
-
Abstract
- We report on the recent development of a 32-channel low-noise analog front-end ASIC “KW03” for hard X-ray and gamma-ray detectors. The ASIC aims for the readout of strip or pixel (pad) detectors utilizing silicon and cadmium telluride (CdTe) as detector materials. Each readout channel includes a charge-sensitive amplifier, bandpass filters and a sample-and-hold circuit. It also includes a leakage current compensation and pole-zero cancellation circuits to meet the various detector requirements. The equivalent noise level of a typical channel reaches 89 e^- @ 0 pF (rms) and shows an input-capacitance characteristic of 7.5 e^-/pF between 0 pF and 10 pF with a power consumption of 3 mW per channel. We mounted the ASIC on a low-temperature co-fired ceramic (LTCC) package and evaluated the spectral performance by combining with a CdTe diode detector. As a result, the gamma-ray spectrum of radioactive source ^241Am was obtained with a good energy resolution of 2.23 keV (FWHM) for gamma rays of 59.5 keV at -\20~^\circC. [ABSTRACT FROM PUBLISHER]
Details
- Language :
- English
- ISSN :
- 00189499
- Volume :
- 57
- Issue :
- 5
- Database :
- Complementary Index
- Journal :
- IEEE Transactions on Nuclear Science
- Publication Type :
- Academic Journal
- Accession number :
- 54502164
- Full Text :
- https://doi.org/10.1109/TNS.2010.2063038