Back to Search Start Over

Temperature oscillations in loop heat pipe operation.

Authors :
Ku, Jentung
Ottenstein, Laura
Kobel, Mark
Rogers, Paul
Kaya, Tarik
Source :
AIP Conference Proceedings; 2001, Vol. 552 Issue 1, p255, 8p
Publication Year :
2001

Abstract

Loop heat pipes (LHPs) are versatile two-phase heat transfer devices that have gained increasing acceptance for space and terrestrial applications. The operating temperature of an LHP is a function of its operating conditions. The LHP usually reaches a steady operating temperature for a given heat load and sink temperature. The operating temperature will change when the heat load and/or the sink temperature changes, but eventually reaches another steady state in most cases. Under certain conditions, however, the loop operating temperature never really reaches a true steady state, but instead becomes oscillatory. This paper discusses the temperature oscillation phenomenon using test data from a miniature LHP. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
552
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
5662904