Back to Search
Start Over
On the use of the Iodide Iodate Reaction Method for assessing mixing times in continuous flow mixers.
- Source :
- AIChE Journal; Apr2011, Vol. 57 Issue 4, p835-840, 6p, 1 Diagram, 3 Charts, 2 Graphs
- Publication Year :
- 2011
-
Abstract
- It is demonstrated experimentally by example of simple, commercially available T-junctions and by 'unsymmetrical' V-type micromixers that mixing times cannot be derived by applying the Iodide Iodate Reaction Method without considering the specific mixer geometry. Experimental results differ depending on the orientation of the feeds with respect to the inlets. An explanation for the observed effects is suggested. © 2010 American Institute of Chemical Engineers AIChE J, 2011 [ABSTRACT FROM AUTHOR]
- Subjects :
- IODIDES
CHEMICAL reactions
CHEMICAL kinetics
IODATES
GEOMETRY
Subjects
Details
- Language :
- English
- ISSN :
- 00011541
- Volume :
- 57
- Issue :
- 4
- Database :
- Complementary Index
- Journal :
- AIChE Journal
- Publication Type :
- Academic Journal
- Accession number :
- 59226246
- Full Text :
- https://doi.org/10.1002/aic.12313