Copper activation deuterium-tritium neutron yield measurements at the National Ignition Facility.

Authors :
Cooper, G. W.
Ruiz, C. L.
Leeper, R. J.
Chandler, G. A.
Hahn, K. D.
Nelson, A. J.
Torres, J. A.
Smelser, R. M.
McWatters, B. R.
Bleuel, D. L.
Yeamans, C. B.
Knittel, K. M.
Casey, D. T.
Frenje, J. A.
Gatu Johnson, M.
Petrasso, R. D.
Styron, J. D.
Source :
Review of Scientific Instruments; Oct2012, Vol. 83 Issue 10, p10D918-10D918-3, 1p, 1 Diagram, 1 Graph
Publication Year :
2012

Abstract

A DT neutron yield diagnostic based on the reactions, 63Cu(n,2n)62Cu(β+) and 65Cu(n,2n) 64 Cu(β+), has been fielded at the National Ignition Facility (NIF). The induced copper activity is measured using a NaI γ-γ coincidence system. Uncertainties in the 14-MeV DT yield measurements are on the order of 7% to 8%. In addition to measuring yield, the ratio of activities induced in two, well-separated copper samples are used to measure the relative anisotropy of the fuel ρR to uncertainties as low as 5%. [ABSTRACT FROM AUTHOR]