Back to Search Start Over

Capacitive Sensor for Measuring the Filled of Post-Tensioned Ducts. Experimental Setup, Modeling and Signal Processing.

Authors :
Bore, Thierry
Placko, Dominique
Taillade, Frederic
Himbert, Marc
Source :
IEEE Sensors Journal; Feb2013, Vol. 13 Issue 2, p457-465, 9p
Publication Year :
2013

Abstract

This paper presents a newly developed system for bridges post-tensioned devices inspection. These devices are generally composed of cables placed inside a duct, the residual space being filled with a particular cement to avoid corrosion. The nondestructive experimental setup uses a capacitive sensor that gives some relevant information about the electrical properties of the materials located inside the duct. Then, using an original modeling of the interactions between the sensor and the post-tensioned device, a signal processing extracts useful information from the sensors data, like the thickness of an eventual air gap between the cement and the duct. Experimental and theoretical derivations and comparisons are presented in the different parts of this paper. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
1530437X
Volume :
13
Issue :
2
Database :
Complementary Index
Journal :
IEEE Sensors Journal
Publication Type :
Academic Journal
Accession number :
84785123
Full Text :
https://doi.org/10.1109/JSEN.2012.2219392