Back to Search Start Over

The 1998 Baltimore Particulate Matter Epidemiology–Exposure Study: Part 1. Comparison of ambient, residential outdoor, indoor and apartment particulate matter monitoring.

Authors :
WILLIAMS, R O N
SUGGS, J A C K
ZWEIDINGER, R
EVANS, G A R Y
CREASON, J O H N
KWOK, R I C H A R D
RODES, C H A R L E S
LAWLESS, P H I L
SHELDON, L I N D A
Source :
Journal of Exposure Analysis & Environmental Epidemiology; Nov2000, Vol. 10 Issue 6, p518, 15p
Publication Year :
2000

Abstract

A combined epidemiological-exposure panel study was conducted during the summer of 1998 in Baltimore, Maryland. The objectives of the exposure analysis component of the 28-day study were to investigate the statistical relationships between particulate matter (PM) and related co-pollutants from numerous spatial boundaries associated with an elderly population, provide daily mass concentrations needed for the epidemiological assessment, and perform an extensive personal exposure assessment. Repeated 24-h integrated PM[SUB2.5] (n=394) and PM[SUB10] (n=170) data collections corresponding to stationary residential central indoor, individual apartment, residential outdoor and ambient monitoring were obtained using the same sampling methodology. An additional 325 PM[SUB2.5] personal air samples were collected from a pool of 21 elderly ( 65 + years of age) subjects. These subjects were residents of the 18-story retirement facility where residential monitoring was conducted. Mean daily central indoor and residential apartment concentrations were approximately 10 μg/ m[SUP3]. Outdoor and ambient PM[SUB2.5] concentrations averaged 22 μg/m[SUP3] with a daily range of 6.7-59.3 μg/m[SUP3]. The slope of the central indoor/outdoor PM[SUB2.5] mass relationship was 0.38. The average daily ratio of PM[SUB2.5]/PM[SUB10] mass concentrations across the measurement sites ranged from 0.73 to 0.92. Both the central indoor and mean apartment PM[SUB2.5] mass concentrations were highly correlated with the outdoor variables (r>0.94). The lack of traditionally recognized indoor sources of PM present within the facility might have accounted for the high degree of correlation observed between the variables. Results associated with the personal monitoring effort are discussed in depth in Part 2 of this article. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10534245
Volume :
10
Issue :
6
Database :
Complementary Index
Journal :
Journal of Exposure Analysis & Environmental Epidemiology
Publication Type :
Academic Journal
Accession number :
8889661
Full Text :
https://doi.org/10.1038/sj.jea.7500107