Back to Search
Start Over
High-efficiency fast-transient-response V2-controlled boost converter with small ESR capacitor.
- Source :
- Electronics Letters (Wiley-Blackwell); 10/24/2013, Vol. 49 Issue 22, p1402-1404, 2p, 3 Diagrams, 1 Chart, 1 Graph
- Publication Year :
- 2013
-
Abstract
- A high-efficiency fast-transient-response V<superscript>2</superscript>-controlled boost converter with a small equivalent series resistance (ESR) capacitor is presented. The proposed boost converter can achieve a fast and stable load transient response without relying on the ESR of the output capacitor. The switching frequency of the proposed boost converter is 500 kHz for a nominal 2.5-4.2 V input and a 3.3-5 V output application. Experimental results show that the transient recovery time inheriting the advantage of V<superscript>2</superscript> control is shorter than 6.4 μs with the load step from 250 to 20 mA and the highest efficiency can be up to 95.4%. The proposed boost converter has been fabricated with a 0.35 μm 2P4M CMOS process, the total chip area is about 1.5 × 1.5 mm<superscript>2</superscript>, including the PADs. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00135194
- Volume :
- 49
- Issue :
- 22
- Database :
- Complementary Index
- Journal :
- Electronics Letters (Wiley-Blackwell)
- Publication Type :
- Academic Journal
- Accession number :
- 95604845
- Full Text :
- https://doi.org/10.1049/el.2013.2772