Back to Search Start Over

A Calculation Method for CO2 Emission in Utility Boilers Based on BP Neural Network and Carbon Balance.

Authors :
Yin, Libao
Liu, Guicai
Zhou, Jielian
Liao, Yanfen
Ma, Xiaoqian
Source :
Energy Procedia; Dec2016, Vol. 105, p3173-3178, 6p
Publication Year :
2016

Abstract

For the accurate calculation of CO 2 emission in utility boilers, the calculation model of CO 2 emission suitable for most coal-fired boilers is built. In this model, BP neural networks were adopted to predict the carbon content of burning coal. This model took the proximate analysis data and fuel consumption flow / coal consumption as inputs, and output the CO 2 emission. Under the BP network prediction model, the average difference of carbon content of burning coal was about 1.80%, while that of CO 2 emission were 3.92% and 0.96%. Compared with emission factor method and capacity standard method, the method in this paper is more suitable to count the CO 2 emission of utility boilers. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
18766102
Volume :
105
Database :
Supplemental Index
Journal :
Energy Procedia
Publication Type :
Academic Journal
Accession number :
123339705
Full Text :
https://doi.org/10.1016/j.egypro.2017.03.690