80. Advancements in PET image reconstruction algorithms: Preliminary results of their application.

Authors :
Matheoud, R.
Bergesio, F.
Chiesa, C.
De Ponti, E.
Morzenti, S.
Ragazzoni, M.
Chauvie, S.
Source :
Physica Medica; 2018 Supplement 2, Vol. 56, p112-112, 1p
Publication Year :
2018

Abstract

Purpose Important advancements have been made in PET image reconstruction algorithms, among the newest point spread function (PSF) and noise statistics modelling (NSM) can be accounted for. This work presents the preliminary results of the application of these reconstruction techniques on 3 state-of-the-art PET/CT scanners with and without time-of-flight (TOF) technique. Methods A Ge68 NEMA/IEC phantom (Data Spectrum, Durham, NC) filled with 68Ge in an epoxy resin was used. The activity concentrations in the spheres and in the background were measured with a radionuclide calibrator tested against a NIST traceable source and were respectively 40.67 kBq/ml and 10.58 kBq/ml at reference time (uncertainty ± 3)%. Nominal sphere-to-background ratio was 3.84. Total activity in the phantom was 108.4 MBq. The phantom was acquired for a prolonged time according to decay correction equivalent to 1.5 min per frame at the reference date on each PET scanner and reconstructed with clinical reconstruction parameters with traditional (OSEM) and by combining advanced modalities, when present: PSF, TOF, TOF + PSF, NSM. For each PET scanner and each reconstruction modality the maximum Recovery Coefficient (RCmax) values were evaluated for each visible sphere. RCmax were normalised to background activity to cancel calibration bias among scanners. Results The Figure presents the RCmax averaged on the 3 PET/CT scanners together with the RC limits suggested by EARL. Error bars represent one standard deviation. Conclusions the RC obtained with the 3 state-of-the-art non digital PET/CT scanners demonstrate clearly that, independently of the reconstruction method used, modern PET/CT scanner outperforms respect to older one described by EARL curve. Moreover, applying more advanced reconstruction techniques progressively enhances RC, NSM reconstruction being the most promising setup. Even if RCmax of different scanners converge at larger (>22 mm) and smaller (10 mm) spheres, the overestimations observed in the size between 1 and 2 cm are currently under investigation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
11201797
Volume :
56
Database :
Supplemental Index
Journal :
Physica Medica
Publication Type :
Academic Journal
Accession number :
134017193
Full Text :
https://doi.org/10.1016/j.ejmp.2018.04.090