Back to Search
Start Over
Concurrent Criterion-related Validity, Reliability, and Responsiveness to Treatment of the Figure-of-Four Position for Measurement of Anterior Hip Joint Structures Tightness.
- Source :
- Journal of Manipulative & Physiological Therapeutics; Nov2018, Vol. 41 Issue 9, p780-788, 9p
- Publication Year :
- 2018
-
Abstract
- Abstract Objective The objective of this study was to examine the intra- and intertester reliability, concurrent criterion-related validity, and responsiveness to treatment of the "figure-of-four" position. Methods A total of 52 asymptomatic male soccer players participated in this study. The intraclass correlation coefficient (2, 1) was used to determine intra- and intertester reliability of the figure-of-four position. Pearson product moment correlation coefficients examining the association between the figure-of-four position and goniometric measurements of hip extension and external rotation were used to establish concurrent validity. To evaluate responsiveness to treatment, the figure-of-four position was assessed by a blinded examiner before and immediately after the application of a stretching technique or control intervention. Results Excellent reliability (intraclass correlation coefficient > 0.75) was obtained for both intra- and intertester reliability of the figure-of-four position. Overall, the figure-of-four position and goniometric measurements of both hip extension and external rotation were significantly correlated. However, no significant treatment effects were observed for the figure-of-four position. Conclusion The results of this study demonstrated that the figure-of-four position is a reliable and valid way to obtain information on tightness of anterior hip joint structures in male soccer players. However, responsiveness to treatment of the figure-of-four position should be questioned. [ABSTRACT FROM AUTHOR]
- Subjects :
- ANALYSIS of variance
CONFIDENCE intervals
STATISTICAL correlation
HIP joint
RANGE of motion of joints
RESEARCH methodology
EVALUATION of medical care
RESEARCH evaluation
STATISTICAL sampling
STRETCH (Physiology)
RANDOMIZED controlled trials
INTER-observer reliability
REPEATED measures design
RESEARCH methodology evaluation
MALE athletes
MEASUREMENT of angles (Geometry)
DATA analysis software
DESCRIPTIVE statistics
INTRACLASS correlation
Subjects
Details
- Language :
- English
- ISSN :
- 01614754
- Volume :
- 41
- Issue :
- 9
- Database :
- Supplemental Index
- Journal :
- Journal of Manipulative & Physiological Therapeutics
- Publication Type :
- Academic Journal
- Accession number :
- 135256245
- Full Text :
- https://doi.org/10.1016/j.jmpt.2018.04.004