Effectiveness of the new generation transcatheter aortic valve in the real life studies. Review and meta-analysis.

Authors :
ACCONCIA, M. C.
CARETTA, Q.
MONZO, L.
TANZILLI, G.
SCAVALLI, A. SILI
SERGI, D.
DI LUOZZO, M.
MARCHEI, M.
CHIOCCHI, M.
ROMEO, F.
GAUDIO, C.
Source :
European Review for Medical & Pharmacological Sciences; 2019, Vol. 23 Issue 18, p8018-8027, 10p, 5 Diagrams, 1 Chart
Publication Year :
2019

Abstract

OBJECTIVE: The aim of the meta-analysis was to assess post-procedural outcome of the new generation of transcatheter aortic valve implantation (TAVI) devices, focusing on the transfemoral and balloon-expandable SAPIEN 3 (Edwards Lifesciences Inc., Irvine, CA, USA), the self-expanding CoreValveTM Evolut series R and PRO (R/PRO)TM (Medtronic Inc., Minneapolis, MN, USA) and ACURATE neo™ transcatheter aortic valve (Symetis SA, a Boston Scientific company, Ecublens, Switzerland). MATERIALS AND METHODS: All observational studies were retrieved through PubMed computerized database from January 2014 until June 30th, 2019. The risk difference (RD) with the 95% confidence interval (CI) was used to assess the effectiveness of the intervention under comparison. The primary end point was 30-day mortality. Safety end points included: (i) stroke, (ii) moderate/severe paravalvular leak, and (iii) the need for new permanent pacemaker implantation. RESULTS: Meta-analysis demonstrated no significant differences as regards to either 30-day mortality or stroke for all the groups of prostheses under comparison. ACURATE neo was associated with significantly less new permanent pacemaker implantation compared to SAPIEN 3 (RD: -0.06; 95% CI -0.08 to -0.03; p<0.0001; I2=0%) or to EVOLUT R/PRO (RD: -0.06; 95% CI -0.09 to -0.02; p=0.0009; I2=0%). A significant reduction of new permanent pacemaker need was observed in the group of patients implanted with SAPIEN 3 compared to EVOLUT R/PRO (RD: -0.07; 95% CI -0.09 to -0.04; p<0.00001; I2=7%). The occurrence of moderate/severe leak was significantly increased in the group of patients implanted with ACURATE neo vs. SAPIEN 3 (RD: 0.04; 95% CI 0.02 to 0.05; p<0.00001; I2=0%). No significant differences were found between ACURATE neo vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.02; p=0.69; I2=0%) and between SAPIEN 3 vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.01; p=0.28; I2=73%). CONCLUSIONS: The results of the meta-analysis show that: (1) ACURATE neo was associated with significantly less new permanent pacemaker implantation than SAPIEN 3 and EVOLUT R/PRO; (2) SAPIEN 3 had significantly lower occurrence of moderate/severe valvular leak than ACURATE neo. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
11283602
Volume :
23
Issue :
18
Database :
Supplemental Index
Journal :
European Review for Medical & Pharmacological Sciences
Publication Type :
Academic Journal
Accession number :
139226793