- The objective of this study was to compare the perioperative and midterm results of Zenith Bifurcated Iliac Side (ZBIS; Cook Medical, Bloomington, Ind) and Gore Iliac Branch Endoprosthesis (IBE; W. L. Gore & Associates, Flagstaff, Ariz) iliac branch devices (IBDs) in treatment of dilated iliac bifurcations in patients with similar anatomic and clinical preoperative features. Between July 2007 and May 2018, 190 IBDs were implanted at two high-volume Italian vascular and endovascular centers. Among the series, preoperative propensity score matching based on preoperative anatomic and clinical factors was performed, and two homogeneous groups were created: group 1, 35 Cook ZBIS IBD implants; and group 2, 35 Gore IBE devices. Early results were analyzed in terms of technical success, death, conversion to open surgery, and occurrence of major local and systemic complications. Follow-up results were analyzed in terms of patency of the IBD, freedom from type I and type III endoleaks, aneurysm-related reintervention, and aneurysm-related death. Technical success was achieved in all implants from both groups. Perioperative IBD-related complications and major complications occurred in one case from group 1 (P =.49). No perioperative mortality was recorded in the two groups. Mean postoperative follow-up was 46.7 months in group 1 (standard deviation, ± 36.3) and 20.8 months in group 2 (standard deviation, ± 15.9; P <.0001). None of the IBDs or target hypogastric arteries occluded during follow-up in this series. Estimated 36-month freedom from type I and type III endoleaks was 97% (standard error [SE], 0.03) in group 1 and 87% (SE, 0.09) in group 2 (P =.34; log-rank, 0.9). Estimated freedom from IBD-related reintervention was 97% (SE, 0.03) in group 1 and 93% (SE, 0.06) in group 2 (P =.81; log-rank, 0.05). The estimated rates of overall survival at 36 months from the IBD implantation were 95% (SE, 0.04) in group 1 and 88% (SE, 0.08) in group 2 (P =.03; log-rank, 4.7); freedom from aneurysm-related death was 100% in group 1 and 93% (SE, 0.06) in group 2 (P =.19; log-rank, 1.7). The propensity score-matched comparison between the Cook ZBIS and Gore IBE devices showed similar, satisfying perioperative and midterm results in the experience of two high-volume Italian vascular centers. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 07415214
- Volume :
- 71
- Issue :
- 4
- Database :
- Supplemental Index
- Journal :
- Journal of Vascular Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 142318009
- Full Text :
- https://doi.org/10.1016/j.jvs.2019.07.058