Lead selection and implantation technique for biventricular pacing.
- Source :
- European Heart Journal--Supplements; Aug2004, pD112-D116, 0p
- Publication Year :
- 2004
-
Abstract
- Based on the recent experience of 464 patients with left ventricular pacing, we report on specific characteristics of various leads and lead types for left ventricular stimulation. In addition to describing the technique and indications for epicardial lead usage, commercially available coronary vein leads are introduced and discussed. Since there is no universally applicable coronary vein lead, the individually optimal lead choice and the sequelae of an erroneous lead selection are described in typical clinical examples. [Copyright &y& Elsevier]