Reproducibility of pulmonary vein isolation guided by the ablation index: One-year outcome of the AIR registry.

Authors :
Lepillier, A.
Solimene, F.
De Ruvo, E.
Scaglione, M.
Anselmino, M.
Sebag, F.
Pecora, D.
Gallagher, M.
Rillo, M.
Stabile, G.
Source :
Archives of Cardiovascular Diseases Supplements; Jan2021, Vol. 13 Issue 1, p89-90, 2p
Publication Year :
2021

Abstract

Arial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multi-centre study was designed to evaluate the reproducibility of PV isolation guided by the AI. A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter [a contact force (ST) or contact force surround flow (STSF) catheter] and the AI setting (330 at posterior and 450 at anterior wall or 380–500). Radiofrequency energy was delivered targeting interlesion distance ≤ 6 mm. At 12 months' follow-up a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs. 83.3%, P = 0.039). There was no difference in the rate of atrial arrhythmias recurrence among the four study groups (4.5% in Group ST330–450, 12.2% in Group ST 380–500, 14.9% in Group STSF330–450, 9.4% in Group STSF380–500, P = 0.083). At 12 months' follow-up, the rate of atrial arrhythmias recurrence was also similar between patients treated with a ST catheter (8%) and STSF catheter (12.1%, P = 0.2), between patients treated with an AI settings of 330–450 (10.9%) and an AI of 380–500 (10.3%, P = 0.64), and among the several operators (P = 0.84 and P = 0.75 respectively in patients with paroxysmal and persistent AF) (Fig. 1). An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of one-year freedom from AF recurrence, both in patients with paroxysmal and persistent AF, irrespective of the ablation catheters, AI settings, and operator. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
18786480
Volume :
13
Issue :
1
Database :
Supplemental Index
Journal :
Archives of Cardiovascular Diseases Supplements
Publication Type :
Academic Journal
Accession number :
147993775
Full Text :
https://doi.org/10.1016/j.acvdsp.2020.10.202