Back to Search
Start Over
Influence of Lumbar Mobilizations During the Nordic Hamstring Exercise on Hamstring Measures of Knee Flexor Strength, Failure Point, and Muscle Activity: A Randomized Crossover Trial.
- Source :
- Journal of Manipulative & Physiological Therapeutics; Jan2021, Vol. 44 Issue 1, p1-13, 13p
- Publication Year :
- 2021
-
Abstract
- The aims of this study were to quantify the effects of spinal mobilization on force production, failure point, and muscle activity of the hamstrings during the Nordic hamstring exercise (NHE), and to explore individual differences in responses. In a replicated randomized crossover trial, 24 asymptomatic, recreationally active men (age [mean ± standard deviation]: 27 ± 6 years; body mass: 82 ± 17 kg; height: 181 ± 8 cm) completed 2 standardized intervention trials (L4/5 zygapophyseal mobilizations) and 2 control trials. The failure point of the NHE was determined with 3D motion capture. Peak force, knee flexor torque, and electromyography (EMG) of the biceps femoris were measured. Data analyses were undertaken to quantify mean intervention response and explore any individual response heterogeneity. Mean (95% confidence interval) left-limb force was higher in intervention than in control trials by 18.7 (4.6-32) N. Similarly, right-limb force was higher by 22.0 (3.4-40.6) N, left peak torque by 0.14 (0.06-0.22) N • m, and right peak torque by 0.14 (0.05-0.23) N • m/kg. Downward force angle was decreased in intervention vs control trials by 4.1° (0.5°-7.6°) on the side of application. Both peak EMG activity (P =.002), and EMG at the downward force (right; P =.020) increased in the intervention condition by 16.8 (7.1-26.4) and 8.8 (1.5-16.1) mV, respectively. Mean downward acceleration angle changed by only 0.3° (−8.9° to 9.4°) in intervention vs control trials. A clear response heterogeneity was indicated only for right force (Participant × Intervention interaction: P =.044; response heterogeneity standard deviation = 34.5 [5.7-48.4] N). Individual response heterogeneity was small for all other outcomes. After spinal mobilization, immediate changes in bilateral hamstring force production and peak torque occurred during the NHE. The effect on the NHE failure point was unclear. Electromyographic activity increased on the ipsilateral side. Response heterogeneity was generally similar to the random trial-to-trial variability inherent in the measurement of the outcomes. [ABSTRACT FROM AUTHOR]
- Subjects :
- KNEE physiology
LUMBAR vertebrae physiology
SKELETAL muscle physiology
BIOMECHANICS
CONFIDENCE intervals
CROSSOVER trials
ELECTROMYOGRAPHY
EXERCISE
EXERCISE physiology
RANGE of motion of joints
KINEMATICS
MUSCLE strength
PHYSICAL therapy
STATISTICAL sampling
TORQUE
THREE-dimensional imaging
PILOT projects
HAMSTRING muscle
RANDOMIZED controlled trials
TREATMENT effectiveness
MOTION capture (Human mechanics)
DESCRIPTIVE statistics
Subjects
Details
- Language :
- English
- ISSN :
- 01614754
- Volume :
- 44
- Issue :
- 1
- Database :
- Supplemental Index
- Journal :
- Journal of Manipulative & Physiological Therapeutics
- Publication Type :
- Academic Journal
- Accession number :
- 148449373
- Full Text :
- https://doi.org/10.1016/j.jmpt.2020.09.005