Back to Search Start Over

Preventing atrial fibrillation by combined right isthmus ablation and cryoballoon pulmonary vein isolation in patients with typical atrial flutter: PAF‐CRIOBLAF study.

Authors :
Anselme, Frédéric
Savouré, Arnaud
Clémenty, Nicolas
Cesari, Olivier
Pavin, Dominique
Jesel, Laurence
Defaye, Pascal
Boveda, Serge
Rivat, Philippe
Mansourati, Jacques
Mechulan, Alexis
Cebron, Jean‐Pierre
Lande, Gilles
Bubenheim ScD, Michael
Milhem, Antoine
Source :
Journal of Arrhythmia; Oct2021, Vol. 37 Issue 5, p1303-1310, 8p
Publication Year :
2021

Abstract

Background: Although less common, typical atrial flutter shares similar pathophysiological roots with atrial fibrillation. Following successful cavo‐tricuspid isthmus ablation using radiofrequency, many patients, however, develop atrial fibrillation in the mid‐to‐long‐term. This study sought to assess whether pulmonary vein isolation conducted at the same time as cavo‐tricuspid isthmus ablation would significantly modify the atrial fibrillation burden upon follow‐up in patients suffering from typical atrial flutter. Methods: This was a multicenter randomized controlled study involving typical atrial flutter patients with history of non‐predominant atrial fibrillation (1 atrial fibrillation episode only, in 67% of population) who were scheduled for cavo‐tricuspid isthmus radiofrequency ablation. Patients were randomly assigned to either undergo cavo‐tricuspid isthmus ablation alone or cavo‐tricuspid isthmus plus pulmonary vein isolation (CTI+). Pulmonary vein isolation was performed using cryoballoon technology. An outpatient consultation with ECG and 1‐week Holter monitoring was performed at 3, 6 months, 1 year, and 2 years postprocedure. The primary endpoint was atrial fibrillation recurrences lasting more than 30 s at 2 years postablation. Results: Of the patients enrolled, 36 were included in each group. At 2‐year follow‐up, the atrial fibrillation recurrence rate was significantly higher in the CTI vs CTI+group (25/36, 69% vs. 12/36, 33% respectively; P <.001), with similar typical atrial flutter recurrence rates. There were no differences in undesirable events, except for transient phrenic nerve palsy reported from three CTI+patients (8.3%). Conclusion: Pulmonary vein isolation using cryoballoon technology was proven to significantly reduce the atrial fibrillation incidence at 2 years postcavo‐tricuspid isthmus ablation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
18832148
Volume :
37
Issue :
5
Database :
Supplemental Index
Journal :
Journal of Arrhythmia
Publication Type :
Academic Journal
Accession number :
152762443
Full Text :
https://doi.org/10.1002/joa3.12626