Back to Search
Start Over
Final 3-Year Outcomes of a Randomized Trial Comparing a Self-Expanding to a Balloon Expandable Transcatheter Aortic Valve.
- Source :
- Circulation: Cardiovascular Interventions; Jul2023, Vol. 16 Issue 7, p456-463, 8p
- Publication Year :
- 2023
-
Abstract
- BACKGROUND: In the SCOPE I trial (Safety and Efficacy of the Symetis ACURATE Neo/TF Compared to the Edwards SAPIEN 3 Bioprosthesis), transcatheter aortic valve implantation with the self-expanding ACURATE neo (NEO) did not meet noninferiority compared with the balloon-expandable SAPIEN 3 (S3) device regarding a composite end point at 30 days due to higher rates of prosthetic valve regurgitation and acute kidney injury. Data on long-term durability of NEO are scarce. Here, we report whether early differences between NEO and S3 translate into differences in clinical outcomes or bioprosthetic valve failure 3 years after transcatheter aortic valve implantation. METHODS: Patients with severe aortic stenosis were randomized to transfemoral transcatheter aortic valve implantation with NEO or S3 at 20 European centers. Clinical outcomes at 3 years are compared using Cox proportional or Fine-Gray subdistribution hazard models by intention-to-treat. Bioprosthetic valve failure is reported for the valve-implant cohort. RESULTS: Among 739 patients, 84 of 372 patients (24.3%) had died in the NEO and 85 of 367 (25%) in the S3 group at 3 years. Comparing NEO with S3, the 3-year rates of all-cause death (hazard ratio, 0.98 [95% CI, 0.73–1.33]), stroke (subhazard ratio, 1.04 [95% CI, 0.56–1.92]), and hospitalization for congestive heart failure (subhazard ratio, 0.74 [95% CI, 0.51–1.07]) were similar between the groups. Aortic valve reinterventions were required in 4 NEO and 3 S3 patients (subhazard ratio, 1.32 [95% CI, 0.30–5.85]). New York Heart Association functional class ≤II was observed in 84% (NEO) and 85% (S3), respectively. Mean gradients remained lower after NEO at 3 years (8 versus 12 mm Hg; P<0.001). CONCLUSIONS: Early differences between NEO and S3 did not translate into significant differences in clinical outcomes or bioprosthetic valve failure throughout 3 years. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 19417640
- Volume :
- 16
- Issue :
- 7
- Database :
- Supplemental Index
- Journal :
- Circulation: Cardiovascular Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 165477495
- Full Text :
- https://doi.org/10.1161/CIRCINTERVENTIONS.123.012873