Off-label use of muscular VSD device for closure of a rare congenital portosystemic shunt.

Authors :
Agha, Hala Mounir
Mashoor, Shady
Ghobashy, Mohamed
AbdelMassih, Antoine
Gaber, Hanya
El-Karaksy, Hanaa
Source :
Egyptian Heart Journal; 3/23/2024, Vol. 76 Issue 1, p1-5, 5p
Publication Year :
2024

Abstract

Background: Congenital portosystemic shunt (CPSS) is a vascular malformation in which portal blood drains toward the systemic circulation, leading to pulmonary hypertension. Case presentation: A 10-year-old patient was brought for evaluation because of dyspnea on exertion. Echocardiography revealed a pulmonary hypertension of 75 mmHg, and multi-slice CT angiography revealed the presence of a CPSS. Closure was finally implemented using a muscular ventricular septal defect device. Follow-up of the patient revealed a gradual decline in pulmonary hypertension. Conclusions: CPSS is an overlooked cause of reversible pulmonary hypertension (PH). Closure of such lesions and reversal pulmonary hypertension are possible via catheterization. The preferred device type depends largely on the intervening team. Plugs are the first choice for interventional radiologists, while ventricular and atrial septal occluder devices and duct occluders are preferred by pediatric cardiologists. [ABSTRACT FROM AUTHOR]